Using troponin I to predict MACE after CABG

  • Siti Elkana Nauli Department of Cardiology and Vascular Medicine, Faculty of Medi-cine University of Indonesia, and National Cardiovascular Center Harapan Kita, Jakarta
  • Ganesja M Harimurti Department of Cardiology and Vascular Medicine, Faculty of Medi-cine University of Indonesia, and National Cardiovascular Center Harapan Kita, Jakarta
  • Nani Hersunarti Department of Cardiology and Vascular Medicine, Faculty of Medi-cine University of Indonesia, and National Cardiovascular Center Harapan Kita, Jakarta

Abstract

Background. CABG has impact in morbidity and mortality. Early detection for which patients will develop these outcomes should be done, especially in patients with low risk for morbidity and mortality after CABG. Elevated troponin I level is common after CABG but its prognostic value still confus-ing due to its lack of cut-off point. This phenomenon has an independent prognostic value for short and long term outcomes. The aim of this of this study was to find out the cut off value of troponin I which could predict MACE 30-day after elective isolated CABG.
Methods. This is a retrospective cohort study included 284 patients after elective CABG. The CKMB level was measured on the 1st and 12nd hour after CABG, while the troponin I level was measured on 8th hours after CABG. We used the ROC curve for troponin I cut-off point. MACE in this research were heart failure or worsening heart failure, low cardiac output syndrome, and death in 30-day after elective isolated CABG.
Results.There were 284 patients who were included in this research, 20,7% had MACE during 30 day after CABG. From bivariate analysis, his-tory of heart failure before CABG, ejection fraction less than 50% before operation, and troponin I level = 5 ng/ml was significantly predicts 30-days MACE after CABG. While from the multivariate analysis showed history of heart failure and troponin I level = 5 ng/ml was significantly increases MACE with OR 3 and 6,88. Troponin I was an independent predictor of MACE with sensitivity 70%.
Conclusion.Troponin I was an independent predictor for 30-days MACE after elective isolated CABG with cut-off value 5 ng/ml.

Downloads

Download data is not yet available.

References

Moosbauer W, Hofer A, Gombotz H.Prevention and Manage-ment of Cardiac Dysfunction during and after Cardiac Surgery. In Atlee JL, Gullo A, Sibagra G, Vincent JL editors. Perioperatif Critical Care Cardiology. 2nd ed. Italia: Springer;2007. p.225-34.

Bojar RM, Wagner KG.Perioperative myocardial infarc-tion. In : Manual of perioperatif care in cardiac surgery.3rd ed.Massachusetts:Blacwell science; 2005: 256-9.

Laporan Tahunan ICU bedah dewasa Pusat Jantung Nasional Harapan Kita tahun 2008 .

Taofan. Faktor Risiko Kematian 30 hari paska bedah pintas arteri koroner.[thesis akhir sebagai syarat menyelesaikan pendidikan spesialis] Departemen Kardiologi dan Kedokteran Vaskular FKUI, Jakarta 2008.

Nesher N, Alghamdi AA, Singh SK, Sever JY, Christakis GT, Goldman BS, et al. Troponin after cardiac surgery : A predictor or a phenomenon? Ann Thorac Surg 2008;85:1348-54.

Bonnefoy E, Filley S, Guidollet J, Girard C, Chevalier P, Kirkorian G, Robin J, Champsaur G, Lehot JJ, Touboul P. Cardiac troponin I to diagnose perioperative myocardial infarction after coronary artery bypass surgery. Eur Heart J 1995;16(Suppl.):325.

Eigel P, Van Ingen G, Wagenpfeil. Predictive value of periopera- Predictive value of periopera-tive cardiac troponin I for adverse outcome in coronary artery bypass surgery. European Journal of Cardio-thoracic Surgery 2001;20:544-9.

Stearns JD, Roman VGD, Barzilai B, Thompson RE, Grogon KL, Thomas B, et al. Prognostic value of troponin I levels for predicting adverse cardiovascular outcomes in postmenopausal women undergoing cardiac surgery. Anest Analg 2009;108:719-26.

Croal BL, Hillis GS, Gibson PH, Fazal MT, El-Shafei H, Gibson G, et al. Relationship between postoperative cardiac troponin I levels and outcome of cardiac surgery. Circulation 2006;114:1468-75.

Yousif H, Davies G, Westaby S, Frendiville OF, Sapsford RN, Oakley CM. Preoperative myocardial ischaemia : its relation to perioperative infarction. Br Heart J 1987;58:9-14.
Views & Downloads
Abstract views: 2631   
PDF (Bahasa Indonesia) downloads: 2534   
How to Cite
Nauli, S., Harimurti, G., & Hersunarti, N. (1). Using troponin I to predict MACE after CABG. Indonesian Journal of Cardiology, 31(2), 101-109. https://doi.org/10.30701/ijc.v31i2.142
Section
Clinical Research